149 research outputs found

    Development of a novel wearable system for real-time measurement of the inter-foot distance during gait

    Get PDF
    The combination of magneto-inertial measurement unit (MIMU) and distance sensor (DS) represents smart solution for evaluating the distance between feet during various daily-life activities. In particular, when analyzing gait, the latter technology can be used for estimating the instantaneous or average distance between selected points of the feet (IFD) during mid-swing and mid-stance phases. The aim of this preliminary work is twofold: a) to develop and validate a novel wearable system for the measurement of the IFD during gait; b) to investigate the optimal positioning of the DS on the foot. Preliminary results showed that the innovative wearable system can be effectively used for accurately measuring the IFD during gait. Interestingly, the accuracy of the IFD estimation is highly affected by the position of the DS on the foot

    A wearable solution for accurate step detection based on the direct measurement of the inter-foot distance

    Get PDF
    Accurate step detection is crucial for the estimation of gait spatio-temporal parameters. Although several step detection methods based on the use of inertial measurement units (IMUs) have been successfully proposed, they may not perform adequately when the foot is dragged while walking, when walking aids are used, or when walking at low speed. The aim of this study was to test an original step-detection method, the inter-foot distance step counter (IFOD), based on the direct measurement of the distance between feet. Gait data were recorded using a wearable prototype system (SWING2DS), which integrates an IMU and two time-of-flight distance sensors (DSs). The system was attached to the medial side of the right foot with one DS positioned close to the forefoot (FOREDS) and the other close to the rearfoot (REARDS). Sixteen healthy adults were asked to walk over ground for two minutes along a loop, including both rectilinear and curvilinear portions, during two experimental sessions. The accuracy of the IFOD step counter was assessed using a stereo-photogrammetric system as gold standard. The best performance was obtained for REARDS with an accuracy higher than 99.8% for the instrumented foot step and 88.8% for the non-instrumented foot step during both rectilinear and curvilinear walks. Key features of the IFOD step counter are that it is possible to detect both right and left steps by instrumenting one foot only and that it does not rely on foot impact dynamics. The IFOD step counter can be combined with existing IMU-based methods for increasing step-detection accuracy

    An objective assessment to investigate the impact of turning angle on freezing of gait in Parkinson's disease

    Get PDF
    Freezing of gait (FoG) is often described in subjects with Parkinson's disease (PD) as a sudden inability to continue the forward walking progression. FoG occurs most often during turning, especially at sharp angles. Here, we investigated 180 and 360 degrees turns in two groups: PD subjects reporting FoG (FoG+), and PD subjects without FoG (FoG-). Forty-three subjects (25 FoG+, 18 FoG-) wore an inertial sensor on their back while walking back and forth continuously for 2 min (reversing direction with a 180° turn), and while turning in place for 1 min (alternating 360° turning in opposite directions). Objective measures (turn duration, peak velocity, jerkiness and range of acceleration) were computed during the turns and compared across FoG+ and FoG-groups. Results showed that FoG+ compared to FoG-took significantly a longer time to complete 360° turns than 180° turns. A significant lower turn peak velocity, higher jerkiness and an increased range of medio-lateral acceleration was also found in FoG+. Significant differences between the two groups across the two turning tasks validated the hypothesis that sharper turns might cause higher instability in FoG+ compared to FoG-

    A proximity sensor for the measurement of the inter-foot distance in static and dynamic tasks

    Get PDF
    Measuring the base of support is of paramount importance in determining human stability during gait or balance tests. While wearable inertial sensors have been successfully employed to quantify numerous gait parameters (velocity, stride length, etc), they could not be used to estimate quantities related to the feet relative position. Thus, alternative technological solutions need to be investigated. Some attempts have been made by combining light intensity infrared or ultrasounds sensors with inertial measurement units. Lately, the Infrared Time-of-Flight technology (IR-ToF) has become popular for measuring distances. IR-ToF sensor measures the time an electromagnetic wave needs to travel a distance. The aim of this work was to investigate the feasibility of the use of an IR-ToF sensor for estimating the inter-foot distance (IFD) in both static and dynamic tasks. Very accurate IFD estimates were obtained during Static (MAE%=3.3%) and Oscillation (MAE%=4.1%) conditions, while larger errors during Gait trials (MAE%=19.8%)

    Static and dynamic accuracy of an innovative miniaturized wearable platform for short range distance measurements for human movement applications

    Get PDF
    Magneto-inertial measurement units (MIMU) are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF), allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i) target colors; (ii) sensor-target distances (up to 200 mm) and (iii) sensor-target angles of incidence (AoI) (up to 60°). Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black). Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0°, the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error <1.5 mm. Errors increased up to 3.6 mm (static) and 11.9 mm (dynamic) for AoI equal to ±30°, and up to 7.8 mm (static) and 25.6 mm (dynamic) for AoI equal to ±60°. In addition, the wearable platform was used during a preliminary experiment for the estimation of the inter-foot distance on a single healthy subject while walking. In conclusion, the combination of magneto-inertial unit and IR-ToF technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption, compared to existing technologies

    A machine learning framework for gait classification using inertial sensors: Application to elderly, post-stroke and huntington’s disease patients

    Get PDF
    Machine learning methods have been widely used for gait assessment through the estimation of spatio-temporal parameters. As a further step, the objective of this work is to propose and validate a general probabilistic modeling approach for the classification of different pathological gaits. Specifically, the presented methodology was tested on gait data recorded on two pathological populations (Huntington’s disease and post-stroke subjects) and healthy elderly controls using data from inertial measurement units placed at shank and waist. By extracting features from group-specific Hidden Markov Models (HMMs) and signal information in time and frequency domain, a Support Vector Machines classifier (SVM) was designed and validated. The 90.5% of subjects was assigned to the right group after leave-one-subject-out cross validation and majority voting. The long-term goal we point to is the gait assessment in everyday life to early detect gait alterations

    Bilateral step length estimation using a single inertial measurement unit attached to the pelvis

    Get PDF
    BACKGROUND: The estimation of the spatio-temporal gait parameters is of primary importance in both physical activity monitoring and clinical contexts. A method for estimating step length bilaterally, during level walking, using a single inertial measurement unit (IMU) attached to the pelvis is proposed. In contrast to previous studies, based either on a simplified representation of the human gait mechanics or on a general linear regressive model, the proposed method estimates the step length directly from the integration of the acceleration along the direction of progression. METHODS: The IMU was placed at pelvis level fixed to the subject's belt on the right side. The method was validated using measurements from a stereo-photogrammetric system as a gold standard on nine subjects walking ten laps along a closed loop track of about 25 m, varying their speed. For each loop, only the IMU data recorded in a 4 m long portion of the track included in the calibrated volume of the SP system, were used for the analysis. The method takes advantage of the cyclic nature of gait and it requires an accurate determination of the foot contact instances. A combination of a Kalman filter and of an optimally filtered direct and reverse integration applied to the IMU signals formed a single novel method (Kalman and Optimally filtered Step length Estimation - KOSE method). A correction of the IMU displacement due to the pelvic rotation occurring in gait was implemented to estimate the step length and the traversed distance. RESULTS: The step length was estimated for all subjects with less than 3% error. Traversed distance was assessed with less than 2% error. CONCLUSIONS: The proposed method provided estimates of step length and traversed distance more accurate than any other method applied to measurements obtained from a single IMU that can be found in the literature. In healthy subjects, it is reasonable to expect that, errors in traversed distance estimation during daily monitoring activity would be of the same order of magnitude of those presented

    Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators

    Get PDF
    BACKGROUND: The assessment of the accuracy of the pose estimation of human bones and consequent joint kinematics is of primary relevance in human movement analysis. This study evaluated the performance of selected pose estimators in reducing the effects of instrumental errors, soft tissue artifacts and anatomical landmark mislocations occurring at the thigh on the determination of the knee kinematics. METHODS: The pattern of a typical knee flexion-extension during a gait cycle was fed into a knee model which generated a six-components knee kinematics and relevant marker trajectories. The marker trajectories were corrupted with both instrumental noise and soft tissue artifacts. Two different cluster configurations (4 and 12-marker cluster) were investigated. Four selected pose estimators, a Geometrical method, a SVD-based method, and the Pointer Cluster Technique in the optimized and non optimized version, were analyzed. The estimated knee kinematics were compared to the nominal kinematics in order to evaluate the accuracy of the selected pose estimators. RESULTS: Results have shown that optimal pose estimators perform better than traditional geometric pose estimators when soft tissue artifacts are present. The use of redundant markers improved in some cases the estimation of the dynamics of the kinematics patterns, while it does not reduce the offsets from the nominal kinematics curves. Overall, the best performance was obtained by the SVD-based pose estimator, while the performance of the PCT pose estimator in its optimal version was not satisfactory. However, the knee kinematics errors reached 5 deg for rotations and 10 mm for translations). CONCLUSION: Given the favorable experimental conditions of this study (soft tissue artifacts determined from a young, healthy and non overweight subject), the errors found in estimating the knee kinematics have to be considered unsatisfactory even if the best performing pose estimator is used. Therefore, it is the authors' opinion that the movement analysis research community should make additional efforts in the search of more subject specific error models to increase the accuracy of joint kinematics estimations

    A 2D Markerless Gait Analysis Methodology: Validation on Healthy Subjects

    Get PDF
    A 2D markerless technique is proposed to perform lower limb sagittal plane kinematic analysis using a single video camera. A subject-specific, multisegmental model of the lower limb was calibrated with the subject in an upright standing position. Ankle socks and underwear garments were used to track the feet and pelvis segments, whereas shank and thigh segments were tracked by means of reference points identified on the model. The method was validated against a marker based clinical gait model. The accuracy of the spatiotemporal parameters estimation was found suitable for clinical use (errors between 1% and 3% of the corresponding true values). Comparison analysis of the kinematics patterns obtained with the two systems revealed high correlation for all the joints (0.82<R2<0.99). Differences between the joint kinematics estimates ranged from 3.9 deg to 6.1 deg for the hip, from 2.7 deg to 4.4 deg for the knee, and from 3.0 deg to 4.7 deg for the ankle. The proposed technique allows a quantitative assessment of the lower limb motion in the sagittal plane, simplifying the experimental setup and reducing the cost with respect to traditional marker based gait analysis protocols

    An ISB-consistent Denavit-Hartenberg model of the human upper limb for joint kinematics optimization: validation on synthetic and robot data during a typical rehabilitation gesture

    Get PDF
    Several biomedical contexts such as diagnosis, rehabilitation, and ergonomics require an accurate estimate of human upper limbs kinematics. Wearable inertial measurement units (IMU s) represent a suitable solution because of their unobtrusiveness, portability, and low-cost. However, the time-integration of the gyroscope angular velocity leads to an unbounded orientation drift affecting both angular and linear displacements over long observation interval. In this work, a Denavit-Hartenberg model of the upper limb was defined in accordance with the guidelines of the International Society of Biomechanics and exploited to design an optimization kinematics process. This procedure estimated the joint angles by minimizing the difference between the modelled and IMU-driven orientation of upper arm and forearm. In addition, reasonable constraints were added to limit the drift influence on the final joint kinematics accuracy. The validity of the procedure was tested on synthetic and experimental data acquired with a robotic arm over 20 minutes. Average rms errors amounted to 2.8 deg and 1.1 for synthetic and robot data, respectively. Clinical Relevance - The proposed method has the potential to improve robustness and accuracy of multi-joint kinematics estimation in the general contexts of home-based tele-rehabilitation interventions. In this respect adoption of multi-segmental kinematic model along with physiological joint constraints could contribute to address current limitations associated to unsupervised analysis in terms of monitoring and outcome assessment
    • …